 Slot-type Reflective Photomicrosensor
EE-SPX301/401 EE-SPY30/40
CSM_EE-SPX301_401_EE-SPY30_40_DS_E_4_1
Photomicrosensor with light modulation is not influenced by external light.
* Voltage-output models with wide operating voltage range (5 to 24 VDC). * Fitted with an easy-to-adjust optical axis mark. * Easy adjustment and optical axis monitoring with a light indicator.
Be sure to read Safety Precautions on page 5.
Ordering Information
Sensors
Appearance Sensing method Sensing distance Output type Output configuration Dark-ON Through-beam type (with slot)
Infrared light
Model EE-SPX301
3.6 mm (slot width)
Light-ON EE-SPX401
Horizontal type Reflective type
Dark-ON
EE-SPY301
5 mm
NPN output Light-ON EE-SPY401
Vertical type Reflective type
Dark-ON
EE-SPY302
5 mm
Light-ON EE-SPY402
Accessories (Order Separately)
Type Connector with Cable NPN/PNP Conversion Connector Connector Hold-down Clip
* Refer to Accessories for details.
Cable length 1m 0.46 m (total length)
Connector
Model EE-1002 EE-1003 EE-2001 EE-1003A
Remarks
For EE-1003 only.
1
EE-SPX301/401 EE-SPY30/40
Ratings and Specifications
Sensing method Item Sensing distance Sensing object Differential distance Light source Indicator *2 Supply voltage Current consumption Models Through-beam type (with slot) EE-SPX301, EE-SPX401 3.6 mm (slot width) Opaque: 1 x 0.5 mm min. 0.05 mm max. GaAs infrared LED with a peak wavelength of 940 nm Light indicator (red) 5 to 24 VDC 10%, ripple (p-p): 5% max. Average: 15 mA max., Peak: 50 mA max. NPN voltage output: Load power supply voltage: 5 to 24 VDC Load current: 80 mA max. OFF current: 0.5 mA max. 80 mA load current with a residual voltage of 1.0 V max. 10 mA load current with a residual voltage of 0.4 V max. 500 Hz min. Operating: -10 to +55C Storage: -25 to +65C (with no icing) Operating: 5% to 85% Storage: 5% to 95% (with no condensation) Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 h each in X, Y, and Z directions Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions IEC IP50 Special connector (soldering not possible) Approx. 2.6 g Case Polycarbonate 100 Hz min. 3,000 lx max. with incandescent light or sunlight on the surface of the receiver Reflective type EE-SPY301, EE-SPY401 EE-SPY302, EE-SPY402 5 mm (Reflection factor: 90%; white paper 15 x 15 mm) *1 --0.2 mm max. (with a sensing distance of 3 mm, horizontally)
Control output
Response frequency *3 Ambient illumination Ambient temperature range Ambient humidity range Vibration resistance Shock resistance Degree of protection Connecting method Weight Material
*1. Operation may not be possible near the Sensor. *2. The indicator is a GaP red LED (peak wavelength: 700 nm). *3. The response frequency was measured by detecting the following rotating disk.
EE-SPX301 EE-SPX401
Disk
EE-SPY30@ EE-SPY40@
200 mm dia.
15 mm
15 mm 15 mm
2 mm
2 mm
2 mm Disk
Disk
2
EE-SPX301/401 EE-SPY30/40
Engineering Data (Typical)
Operating Range Characteristics EE-SPY301, EE-SPY401
Distance Y (mm) 12 11 10 9 8 7 6 5 4 3 2 1 0 -5 -4 -3 -2 -1 0 1 2 3 4 5 X Y Sensing object: White paper (15 x 15 mm2) reflection factor: 90% Operates Releases
EE-SPY301, EE-SPY401
Distance Y (mm) 12 11 10 Sensing object: 9 White paper (15 x 15 mm2) 8 reflection factor: 90% 7 6 5 X 4 3 2 1 0 -5 -4 -3 -2 -1 0 1 2 3 4 5 Operates Releases Y
Distance X (mm)
Distance X (mm)
EE-SPY302, EE-SPY402
Distance Y (mm)
12 11 10 9 8 7 6 X 5 4 3 2 1 0 -5 -4 -3 -2 -1 0 1 2 3 4 5 Y Sensing object: White paper (15 x 15 mm2) reflection factor: 90%
EE-SPY302, EE-SPY402
Distance Y (mm)
12 11 10 9 8 7 6 X 5 4 3 2 1 0 -5 -4 -3 -2 -1 0 1 2 3 4 5 Y Sensing object: White paper (15 x 15 mm2) reflection factor: 90%
Distance X (mm)
Distance X (mm)
Sensing Position Characteristics EE-SPX301 (Z Direction) EE-SPX301 (Y Direction)
Dark ON Tr ON Tr ON
Dark ON
Z
Y
Tr OFF 0
1
2
3
4
5
6
7
8
Tr OFF 0
1
2
3
4
5
6
7
8
Z (mm)
Y (mm)
3
EE-SPX301/401 EE-SPY30/40
Receiver Output Excess Gain vs. Sensing Distance Characteristics EE-SPY@@@
Receiver output excess gain (multiple)
6 Vcc = 24 V Length of cable = 0.5 m Thickness of cable = 0.3 mm2 Sensing object: 2 White paper (15 x 15 mm ) (reflection factor: 90%)
Sensing Distance vs. Object Area Characteristics EE-SPY@@@
Sensing distance (mm)
15
Sensing object: white paper (reflection factor: 90%)
5
l l
10
4
3
2 Operating level
5
1
0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 12 22 32 52 72 102 202 302 502
Distance d (mm)
Sensing area l2 (mm2)
Sensing Angle vs. Sensing Distance Characteristics EE-SPY@@@
Relative sensing distance d (%)
110 100 90 80 Sensing object: 2 White paper (15 x 15 mm ) 60 (reflection factor: 90%) 70 50 40 30 20 10 0 -40 -30 -20 -10 0 10 20 30 40 d + - d + - Vcc = 24 V Length of cable = 0.5 m Thickness of cable = 0.3 mm2 EE-SPY301 EE-SPY302
Dependency on Cable Length for Operation Distance/Release Distance EE-SPY@@@
Operating distance/release distance (mm)
20 18 16 14 12 10 8 6 4 2 0 0.1 0.3 0.5 0.7 1.0 3 (A): Using direct cable extension. (B): Using an externally attached capacitance of 10 F. Operates Releases 5 7 10 Sensing object: 2 White paper (15 x 15 mm ) (reflection factor: 90%) Ta = 25C Vcc = 4.5 V RL = 4.7 k Lead: AWG24 (A)
(B)
C: 10 F Attach externally
Angle ()
Length of cable (m)
4
EE-SPX301/401 EE-SPY30/40
I/O Circuit Diagrams
NPN Output
Model Output configuration Timing charts
Incident Interrupted
Output circuit
EE-SPX401 EE-SPY401 EE-SPY402
Light indicator ON (red) OFF
Light-ON
Output transistor Load 1 (relay) Load 2
ON OFF Operates Releases H L Light indicator (red) 1.5 to 3 mA Main circuit OUT Ic Load 2 Load 1 5 to 24 VDC
Incident Interrupted
EE-SPX301 EE-SPY301 EE-SPY302
Light indicator ON (red) OFF
* Voltage output (when the sensor is connected to a transistor circuit)
Dark-ON
Output transistor Load 1 (relay) Load 2
ON OFF Operates Releases H L
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes
Wiring
* Connection is made using a connector. Do not solder to the pins (leads). * When extending the cable, use an extension cable with conductors having a total cross-section area of 0.3 mm2. The total cable length must be 2 m maximum. * To use a cable length longer than 2 m, attach a capacitor with a capacitance of approximately 10 F to the wires as shown below. The distance between the terminal and the capacitor must be within 2 m. (Use a capacitor with a dielectric strength that is at least twice the Sensor's power supply voltage.)
5 to 24 VDC + - Extension cable 2 m max.
Precautions for Correct Use
Make sure that this product is used within the rated ambient environment conditions.
Mounting
The sensing distance for the EE-SPY Reflective-type Photomicrosensor with built-in amplifier varies from 8 to 20 mm depending on the product (90% reflective white paper). Do not place glossy objects in the background of the sensing object.
OUT
A capacitor of 10 F min.
0V
* Make sure the total length of the power cable connected to the product is less than 10 m even if a capacitor is inserted.
5
EE-SPX301/401 EE-SPY30/40
(Unit: mm)
Dimensions
Sensors
EE-SPX301 EE-SPX401
Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified.
26 20 14 7 3.6 Sensing window (1 x 0.5)
Terminal Arrangement
9 Indicator window (red) Two, 3.2 dia. 6 7.5 3
(1) (2) (3) OUT
18
Vcc OUTPUT GND (0 V)
24
(3)
(2)
(1)
3-0.635 1.25 3 4.2
2.5
5 26 20 14
EE-SPY301 EE-SPY401
7
8
Sensing face 4
Terminal Arrangement (1) Vcc OUT OUTPUT GND (0 V)
20
14
Indicator window (red) Two, 3.2 dia.
(2) (3)
6 7.5
3
(3)
(2)
(1)
3-0.635 1.25 3 4.2
2.5
5 26 20 14
EE-SPY302 EE-SPY402
7 3.5
4 8 Sensing face
Terminal Arrangement (1)
Indicator window (red) 20 Two, 3.2 dia. 6 7.5 3
Vcc OUT OUTPUT GND (0 V)
(2) (3)
(3)
(2)
(1)
3-0.635 1.25 3 4.2
2.5
5
Accessories (Order Separately)
* Refer to Accessories for details.
6
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
2010.8 In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
http://www.ia.omron.com/
OMRON Corporation
(c)Copyright OMRON Corporation 2010 All Right Reserved.


▲Up To Search▲   

 
Price & Availability of EE-SPX301

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X